For supercapacitor failure errors for P2000 storage box you need to check hardware status with this command. If there is no hardware failure ask your vendor to update Firmware also in some cases you need to replace controller.
Error:
Supercapacitor failure. Status: cell 1 voltage is too high (27), State: failure (12) (p2: 3972, p3: 0)
Controls:
Connect CLI and run these CLI commands.And check sensor-status.
How to Check NIC Port Status P2000 storage box?
# show ports Ports Media Target ID Status Speed(A) Speed(C) ----------------------------------------------------------------- A1 FC(L) 207000c0ff10b884 Up 8Gb Auto Topo(C) PID ------------ Loop 0 A2 FC(L) 217000c0ff10b884 Up 8Gb Auto Topo(C) PID ------------ Loop 0 ----------------------------------------------------------------- Ports Media Target ID Status Speed(A) Speed(C) ----------------------------------------------------------------- B1 FC(-) 247000c0ff10b884 Disconnected Auto Topo(C) PID ------------ Loop B2 FC(L) 257000c0ff10b884 Up 8Gb Auto Topo(C) PID ------------ Loop 1 ----------------------------------------------------------------- Success: Command completed successfully.
How to check hadrware status P2000 storage box?
# show enclosure-status Chassis Vendor Product ID CPLD EMP A CH:ID Rev EMP B CH:ID Rev WWPN Status -------------------------------------------------------------------------------------------------------------------------------------- 2S6034B176 HP SPS-CHASSIS 13 01:031 1044 00:031 1044 500c0ff010b8843c OK -------------------------------------------------------------------------------------------------------------------------------------- Type # Status FRU P/N FRU S/N Add'l Data ------------------------------------------------------------------------------- FAN 01 OK 592267-001 CN8028N722 -- FAN 02 OK 592267-001 CN8028N723 -- PSU 01 OK 592267-001 CN8028N722 -- PSU 02 OK 592267-001 CN8028N723 -- Temp 01 OK AP836A CN8030R240 temp=27 Temp 02 OK AP836A CN8030R282 temp=25 Temp 03 OK 592267-001 CN8028N722 temp=24 Temp 04 OK 592267-001 CN8028N723 temp=29 Voltage 01 OK AP836A CN8030R240 voltage=11.92 Voltage 02 OK AP836A CN8030R240 voltage=5.10 Voltage 03 OK AP836A CN8030R282 voltage=11.86 Voltage 04 OK AP836A CN8030R282 voltage=5.08 Voltage 05 OK 592267-001 CN8028N722 voltage=12.01 Voltage 06 OK 592267-001 CN8028N722 voltage=5.12 Voltage 07 OK 592267-001 CN8028N722 voltage=3.68 Voltage 08 OK 592267-001 CN8028N723 voltage=11.97 Voltage 09 OK 592267-001 CN8028N723 voltage=5.11 Voltage 10 OK 592267-001 CN8028N723 voltage=3.70 Disk 01 OK 582939-001 2S6034B176 addr=0 Disk 02 OK 582939-001 2S6034B176 addr=1 Disk 03 OK 582939-001 2S6034B176 addr=2 Disk 04 OK 582939-001 2S6034B176 addr=3 Disk 05 OK 582939-001 2S6034B176 addr=4 Disk 06 OK 582939-001 2S6034B176 addr=5 Disk 07 OK 582939-001 2S6034B176 addr=6 Disk 08 OK 582939-001 2S6034B176 addr=7 Disk 09 OK 582939-001 2S6034B176 addr=8 Disk 10 OK 582939-001 2S6034B176 addr=9 Disk 11 OK 582939-001 2S6034B176 addr=10 Disk 12 OK 582939-001 2S6034B176 addr=11 Disk 13 Absent 582939-001 2S6034B176 addr=12 Disk 14 Absent 582939-001 2S6034B176 addr=13 Disk 15 Absent 582939-001 2S6034B176 addr=14 Disk 16 Absent 582939-001 2S6034B176 addr=15 Disk 17 Absent 582939-001 2S6034B176 addr=16 Disk 18 Absent 582939-001 2S6034B176 addr=17 Disk 19 Absent 582939-001 2S6034B176 addr=18 Disk 20 Absent 582939-001 2S6034B176 addr=19 Disk 21 Absent 582939-001 2S6034B176 addr=20 Disk 22 Absent 582939-001 2S6034B176 addr=21 Disk 23 Absent 582939-001 2S6034B176 addr=22 Disk 24 Absent 582939-001 2S6034B176 addr=23 ------------------------------------------------------------------------------- Success: Command completed successfully. # show expander-status Encl Ctlr Phy Type Status Elem Status Disabled Reason ------------------------------------------------------------------------------------------------------------------- 1 A 0 Drive Enabled-Healthy OK Enabled 1 A 1 Drive Enabled-Healthy OK Enabled 1 A 2 Drive Enabled-Healthy OK Enabled 1 A 3 Drive Enabled-Healthy OK Enabled 1 A 4 Drive Enabled-Healthy OK Enabled 1 A 5 Drive Enabled-Healthy OK Enabled 1 A 6 Drive Enabled-Healthy OK Enabled 1 A 7 Drive Enabled-Healthy OK Enabled 1 A 8 Drive Enabled-Healthy OK Enabled 1 A 9 Drive Enabled-Healthy OK Enabled 1 A 10 Drive Enabled-Healthy OK Enabled 1 A 11 Drive Enabled-Healthy OK Enabled 1 A 12 Drive Disabled OK Disabled Drive removed 1 A 13 Drive Disabled OK Disabled Drive removed 1 A 14 Drive Disabled OK Disabled Drive removed 1 A 15 Drive Disabled OK Disabled Drive removed 1 A 16 Drive Disabled OK Disabled Drive removed 1 A 17 Drive Disabled OK Disabled Drive removed 1 A 18 Drive Disabled OK Disabled Drive removed 1 A 19 Drive Disabled OK Disabled Drive removed 1 A 20 Drive Disabled OK Disabled Drive removed 1 A 21 Drive Disabled OK Disabled Drive removed 1 A 22 Drive Disabled OK Disabled Drive removed 1 A 23 Drive Disabled OK Disabled Drive removed 1 A 0 SC-1 Enabled-Healthy OK Enabled 1 A 1 SC-1 Enabled-Healthy OK Enabled 1 A 0 SC-0 Enabled-Healthy OK Enabled 1 A 1 SC-0 Enabled-Healthy OK Enabled 1 A 2 SC-0 Enabled-Healthy OK Enabled 1 A 3 SC-0 Enabled-Healthy OK Enabled 1 A 0 Egress Enabled-Degraded Non-critical Enabled Not ready 1 A 1 Egress Enabled-Degraded Non-critical Enabled Not ready 1 A 2 Egress Enabled-Degraded Non-critical Enabled Not ready 1 A 3 Egress Enabled-Degraded Non-critical Enabled Not ready ------------------------------------------------------------------------------------------------------------------- Encl Ctlr Phy Type Status Elem Status Disabled Reason ------------------------------------------------------------------------------------------------------------------- 1 B 0 Drive Enabled-Healthy OK Enabled 1 B 1 Drive Enabled-Healthy OK Enabled 1 B 2 Drive Enabled-Healthy OK Enabled 1 B 3 Drive Enabled-Healthy OK Enabled 1 B 4 Drive Enabled-Healthy OK Enabled 1 B 5 Drive Enabled-Healthy OK Enabled 1 B 6 Drive Enabled-Healthy OK Enabled 1 B 7 Drive Enabled-Healthy OK Enabled 1 B 8 Drive Enabled-Healthy OK Enabled 1 B 9 Drive Enabled-Healthy OK Enabled 1 B 10 Drive Enabled-Healthy OK Enabled 1 B 11 Drive Enabled-Healthy OK Enabled 1 B 12 Drive Disabled OK Disabled Drive removed 1 B 13 Drive Disabled OK Disabled Drive removed 1 B 14 Drive Disabled OK Disabled Drive removed 1 B 15 Drive Disabled OK Disabled Drive removed 1 B 16 Drive Disabled OK Disabled Drive removed 1 B 17 Drive Disabled OK Disabled Drive removed 1 B 18 Drive Disabled OK Disabled Drive removed 1 B 19 Drive Disabled OK Disabled Drive removed 1 B 20 Drive Disabled OK Disabled Drive removed 1 B 21 Drive Disabled OK Disabled Drive removed 1 B 22 Drive Disabled OK Disabled Drive removed 1 B 23 Drive Disabled OK Disabled Drive removed 1 B 0 SC-1 Enabled-Healthy OK Enabled 1 B 1 SC-1 Enabled-Healthy OK Enabled 1 B 0 SC-0 Enabled-Healthy OK Enabled 1 B 1 SC-0 Enabled-Healthy OK Enabled 1 B 2 SC-0 Enabled-Healthy OK Enabled 1 B 3 SC-0 Enabled-Healthy OK Enabled 1 B 0 Egress Enabled-Degraded Non-critical Enabled Not ready 1 B 1 Egress Enabled-Degraded Non-critical Enabled Not ready 1 B 2 Egress Enabled-Degraded Non-critical Enabled Not ready 1 B 3 Egress Enabled-Degraded Non-critical Enabled Not ready ------------------------------------------------------------------------------------------------------------------- Success: Command completed successfully. # show sensor-status Sensor Name Value Status ---------------------------------------------------- On-Board Temperature 1-Ctlr A 38 OK On-Board Temperature 1-Ctlr B 36 OK On-Board Temperature 2-Ctlr A 51 OK On-Board Temperature 2-Ctlr B 49 OK On-Board Temperature 3-Ctlr A 39 OK On-Board Temperature 3-Ctlr B 40 OK Disk Controller Temp-Ctlr A 19 OK Disk Controller Temp-Ctlr B 20 OK Memory Controller Temp-Ctlr A 51 OK Memory Controller Temp-Ctlr B 54 OK Capacitor Pack Voltage-Ctlr A 8.17 OK Capacitor Pack Voltage-Ctlr B 8.12 OK Capacitor Cell 1 Voltage-Ctlr A 2.05 OK Capacitor Cell 1 Voltage-Ctlr B 2.03 OK Capacitor Cell 2 Voltage-Ctlr A 2.05 OK Capacitor Cell 2 Voltage-Ctlr B 2.05 OK Capacitor Cell 3 Voltage-Ctlr A 2.02 OK Capacitor Cell 3 Voltage-Ctlr B 2.04 OK Capacitor Cell 4 Voltage-Ctlr A 2.04 OK Capacitor Cell 4 Voltage-Ctlr B 2.00 OK Capacitor Charge-Ctlr A 97% OK Capacitor Charge-Ctlr B 97% OK Overall Unit Status OK OK Temperature Loc: upper-IOM A 47 OK Temperature Loc: lower-IOM B 45 OK Temperature Loc: left-PSU 1 45 OK Temperature Loc: right-PSU 2 48 OK Voltage 12V Loc: upper-IOM A 11.92 OK Voltage 5V Loc: upper-IOM A 5.10 OK Voltage 12V Loc: lower-IOM B 11.86 OK Voltage 5V Loc: lower-IOM B 5.08 OK Voltage 12V Loc: left-PSU 1 11.98 OK Voltage 5V Loc: left-PSU 1 5.12 OK Voltage 3.3V Loc: left-PSU 1 3.68 OK Voltage 12V Loc: right-PSU 2 11.98 OK Voltage 5V Loc: right-PSU 2 5.11 OK Voltage 3.3V Loc: right-PSU 2 3.70 OK Current 12V Loc: upper-IOM A 2.96 OK Current 12V Loc: lower-IOM B 2.96 OK Current 12V Loc: left-PSU 1 3.58 OK Current 5V Loc: left-PSU 1 3.39 OK Current 12V Loc: right-PSU 2 6.14 OK Current 5V Loc: right-PSU 2 2.47 OK ---------------------------------------------------- Success: Command completed successfully. # show controllers Controllers ----------- Controller ID: A Serial Number: CN8030R240 Hardware Version: 53 CPLD Version: 13 MAC Address: 00:C0:FF:10:C9:49 WWNN: 208000c0ff10b884 IP Address: 10.4.94.36 IP Subnet Mask: 255.255.255.0 IP Gateway: 10.4.94.3 Disks: 12 Vdisks: 2 Cache Memory Size (MB): 2048 Host Ports: 2 Disk Channels: 2 Disk Bus Type: SAS Status: Operational Failed Over: No Fail Over Reason: Not applicable Position: Top Phy Isolation: Enabled Controller ID: B Serial Number: CN8030R282 Hardware Version: 53 CPLD Version: 13 MAC Address: 00:C0:FF:10:CD:DC WWNN: 208000c0ff10b884 IP Address: 10.4.94.40 IP Subnet Mask: 255.255.255.0 IP Gateway: 10.4.94.3 Disks: 12 Vdisks: 1 Cache Memory Size (MB): 2048 Host Ports: 2 Disk Channels: 2 Disk Bus Type: SAS Status: Operational Failed Over: No Fail Over Reason: Not applicable Position: Bottom Phy Isolation: Enabled Success: Command completed successfully. # show enclosures Encl Encl WWN Name Location Rack Pos Vendor Model EMP A CH:ID Rev EMP B CH:ID Rev Mid-Plane Type ----------------------------------------------------------------------------------------------------------------------------------------------------------------- 1 500c0ff010b8843c 0 0 HP SPS-CHASSIS 01:031 1044 00:031 1044 2U24-6G ----------------------------------------------------------------------------------------------------------------------------------------------------------------- Success: Command completed successfully. # # show disks Location Serial Number Vendor Rev How Used Type Size Rate*(Gb/s) SP Status ------------------------------------------------------------------------------------------------------------ 1.1 6TB02HBK0000B10404AU HP HPDE VDISK SAS 146.8GB 6.0 Up 1.2 3TB1Z66Y000091054WFW HP HPDE VDISK SAS 146.8GB 6.0 Up 1.3 6TB02HC30000B1042ZNU HP HPDE VDISK SP SAS 146.8GB 6.0 Up 1.4 6TB01ENT0000B1022RUN HP HPDE AVAIL SAS 146.8GB 6.0 Up 1.5 6TB026FS0000B1043NQD HP HPDE VDISK SAS 146.8GB 6.0 Up 1.6 6TB02J770000B1041T2Q HP HPDE VDISK SAS 146.8GB 3.0 Up 1.7 6TB025AA0000B1041U0T HP HPDE VDISK SAS 146.8GB 6.0 Up 1.8 6TB02QS60000B1051CFG HP HPDE VDISK SAS 146.8GB 6.0 Up 1.9 6TB02YF50000B1051CEK HP HPDE VDISK SAS 146.8GB 3.0 Up 1.10 6TB02HRZ0000B103314R HP HPDE VDISK SAS 146.8GB 6.0 Up 1.11 6TB026YW0000B1040LPM HP HPDE VDISK SAS 146.8GB 6.0 Up 1.12 6TB02YH70000B1051CMB HP HPDE VDISK SAS 146.8GB 3.0 Up ------------------------------------------------------------------------------------------------------------ Info: * Rates may vary. This is normal behavior. Success: Command completed successfully. # show network Network Parameters Controller A ------------------------------- IP Address: 10.4.94.36 Gateway: 10.4.94.3 Subnet Mask: 255.255.255.0 MAC Address: 00:C0:FF:10:C9:49 Addressing Mode: Manual Network Parameters Controller B ------------------------------- IP Address: 10.4.94.40 Gateway: 10.4.94.3 Subnet Mask: 255.255.255.0 MAC Address: 00:C0:FF:10:CD:DC Addressing Mode: Manual Success: Command completed successfully.
How to check all configuration and Hardware status for P2000 storage box?
# show configuration System Information ------------------ System Name: P2000-1 System Contact: Uninitialized Contact System Location: Uninitialized Location System Information: Uninitialized Info Vendor Name: HP StorageWorks Product ID: P2000 G3 FC Product Brand: MSA Storage SCSI Vendor ID: HP Enclosure Count: 1 Health: Degraded Supported Locales: English (English), Spanish (español), French (français), German (Deutsch), Italian (italiano), Japanese (日本語), Dutch (Nederlands), Chinese-Simplified (简体ä¸æ–‡), Chinese-Traditional (ç¹é«”ä¸æ–‡), Korean (í•œêµì–´) Controllers ----------- Controller ID: A Serial Number: CN8030R240 Hardware Version: 53 CPLD Version: 13 MAC Address: 00:C0:FF:10:C9:49 WWNN: 208000c0ff10b884 IP Address: 10.4.94.36 IP Subnet Mask: 255.255.255.0 IP Gateway: 10.4.94.3 Disks: 12 Vdisks: 2 Cache Memory Size (MB): 2048 Host Ports: 2 Disk Channels: 2 Disk Bus Type: SAS Status: Operational Failed Over: No Fail Over Reason: Not applicable Position: Top Phy Isolation: Enabled Controller ID: B Serial Number: CN8030R282 Hardware Version: 53 CPLD Version: 13 MAC Address: 00:C0:FF:10:CD:DC WWNN: 208000c0ff10b884 IP Address: 10.4.94.40 IP Subnet Mask: 255.255.255.0 IP Gateway: 10.4.94.3 Disks: 12 Vdisks: 1 Cache Memory Size (MB): 2048 Host Ports: 2 Disk Channels: 2 Disk Bus Type: SAS Status: Operational Failed Over: No Fail Over Reason: Not applicable Position: Bottom Phy Isolation: Enabled Controller A Versions --------------------- Storage Controller CPU Type: Intel Tolapai 1200MHz Bundle Version: TS100R025 Build Date: Thu Mar 11 12:02:53 MST 2010 Storage Controller Code Version: T100R18 Storage Controller Code Baselevel: T100R18 Memory Controller FPGA Code Version: F400R02 Storage Controller Loader Code Version: 23.008 CAPI Version: 3.12 Management Controller Code Version: L100R013 Management Controller Loader Code Version: not set Expander Controller Code Version: 1044 CPLD Code Version: 13 Hardware Version: 53 Host Interface Module Version: 52 Host Interface Module Model: 7 Backplane Type: 7 Host Interface Hardware (Chip) Version: 2 Disk Interface Hardware (Chip) Version: 2 Controller B Versions --------------------- Storage Controller CPU Type: Intel Tolapai 1200MHz Bundle Version: TS100R025 Build Date: Thu Mar 11 12:02:53 MST 2010 Storage Controller Code Version: T100R18 Storage Controller Code Baselevel: T100R18 Memory Controller FPGA Code Version: F400R02 Storage Controller Loader Code Version: 23.008 CAPI Version: 3.12 Management Controller Code Version: L100R013 Management Controller Loader Code Version: not set Expander Controller Code Version: 1044 CPLD Code Version: 13 Hardware Version: 53 Host Interface Module Version: 52 Host Interface Module Model: 7 Backplane Type: 7 Host Interface Hardware (Chip) Version: 2 Disk Interface Hardware (Chip) Version: 2 Ports Media Target ID Status Speed(A) Speed(C) ----------------------------------------------------------------- A1 FC(L) 207000c0ff10b884 Up 8Gb Auto Topo(C) PID ------------ Loop 0 A2 FC(L) 217000c0ff10b884 Up 8Gb Auto Topo(C) PID ------------ Loop 0 ----------------------------------------------------------------- Ports Media Target ID Status Speed(A) Speed(C) ----------------------------------------------------------------- B1 FC(-) 247000c0ff10b884 Disconnected Auto Topo(C) PID ------------ Loop B2 FC(L) 257000c0ff10b884 Up 8Gb Auto Topo(C) PID ------------ Loop 1 ----------------------------------------------------------------- Location Serial Number Vendor Rev How Used Type Size Rate*(Gb/s) SP Status ------------------------------------------------------------------------------------------------------------ 1.1 6TB02HBK0000B10404AU HP HPDE VDISK SAS 146.8GB 6.0 Up 1.2 3TB1Z66Y000091054WFW HP HPDE VDISK SAS 146.8GB 6.0 Up 1.3 6TB02HC30000B1042ZNU HP HPDE VDISK SP SAS 146.8GB 6.0 Up 1.4 6TB01ENT0000B1022RUN HP HPDE AVAIL SAS 146.8GB 6.0 Up 1.5 6TB026FS0000B1043NQD HP HPDE VDISK SAS 146.8GB 6.0 Up 1.6 6TB02J770000B1041T2Q HP HPDE VDISK SAS 146.8GB 3.0 Up 1.7 6TB025AA0000B1041U0T HP HPDE VDISK SAS 146.8GB 6.0 Up 1.8 6TB02QS60000B1051CFG HP HPDE VDISK SAS 146.8GB 6.0 Up 1.9 6TB02YF50000B1051CEK HP HPDE VDISK SAS 146.8GB 3.0 Up 1.10 6TB02HRZ0000B103314R HP HPDE VDISK SAS 146.8GB 6.0 Up 1.11 6TB026YW0000B1040LPM HP HPDE VDISK SAS 146.8GB 6.0 Up 1.12 6TB02YH70000B1051CMB HP HPDE VDISK SAS 146.8GB 3.0 Up ------------------------------------------------------------------------------------------------------------ Status Encl Slot Vendor Model Serial Number Size ------------------------------------------------------------------------------------ Up 1 1 HP EH0146FAWJB 6TB02HBK0000B10404AU 146.8GB Up 1 2 HP EH0146FAWJB 3TB1Z66Y000091054WFW 146.8GB Up 1 3 HP EH0146FAWJB 6TB02HC30000B1042ZNU 146.8GB Up 1 4 HP EH0146FAWJB 6TB01ENT0000B1022RUN 146.8GB Up 1 5 HP EH0146FAWJB 6TB026FS0000B1043NQD 146.8GB Up 1 6 HP EH0146FAWJB 6TB02J770000B1041T2Q 146.8GB Up 1 7 HP EH0146FAWJB 6TB025AA0000B1041U0T 146.8GB Up 1 8 HP EH0146FAWJB 6TB02QS60000B1051CFG 146.8GB Up 1 9 HP EH0146FAWJB 6TB02YF50000B1051CEK 146.8GB Up 1 10 HP EH0146FAWJB 6TB02HRZ0000B103314R 146.8GB Up 1 11 HP EH0146FAWJB 6TB026YW0000B1040LPM 146.8GB Up 1 12 HP EH0146FAWJB 6TB02YH70000B1051CMB 146.8GB Not Present 1 13 N/A N/A N/A N/A Not Present 1 14 N/A N/A N/A N/A Not Present 1 15 N/A N/A N/A N/A Not Present 1 16 N/A N/A N/A N/A Not Present 1 17 N/A N/A N/A N/A Not Present 1 18 N/A N/A N/A N/A Not Present 1 19 N/A N/A N/A N/A Not Present 1 20 N/A N/A N/A N/A Not Present 1 21 N/A N/A N/A N/A Not Present 1 22 N/A N/A N/A N/A Not Present 1 23 N/A N/A N/A N/A Not Present 1 24 N/A N/A N/A N/A ------------------------------------------------------------------------------------ Name Size Free Own Pref RAID Disks Spr Chk Status Jobs Serial Number Drive Spin Down Spin Down Delay --------------------------------------------------------------------------------------------------------------------------------------------------------------- lhsapp01_boot 293.3GB 0B B B RAID10 4 0 64k FTOL 00c0ff10cddc0000028cf74c00000000 Disabled 0 lhsapp01swap_vd10 146.6GB 0B A A RAID1 2 1 N/A FTOL 00c0ff10c94900009c8d925400000000 Disabled 0 lhsdbp00_boot 293.3GB 0B A A RAID10 4 0 64k FTOL 00c0ff10c94900008c67f74c00000000 Disabled 0 --------------------------------------------------------------------------------------------------------------------------------------------------------------- Chassis Vendor Product ID CPLD EMP A CH:ID Rev EMP B CH:ID Rev WWPN Status -------------------------------------------------------------------------------------------------------------------------------------- 2S6034B176 HP SPS-CHASSIS 13 01:031 1044 00:031 1044 500c0ff010b8843c OK -------------------------------------------------------------------------------------------------------------------------------------- Type # Status FRU P/N FRU S/N Add'l Data ------------------------------------------------------------------------------- FAN 01 OK 592267-001 CN8028N722 -- FAN 02 OK 592267-001 CN8028N723 -- PSU 01 OK 592267-001 CN8028N722 -- PSU 02 OK 592267-001 CN8028N723 -- Temp 01 OK AP836A CN8030R240 temp=27 Temp 02 OK AP836A CN8030R282 temp=25 Temp 03 OK 592267-001 CN8028N722 temp=24 Temp 04 OK 592267-001 CN8028N723 temp=29 Voltage 01 OK AP836A CN8030R240 voltage=11.92 Voltage 02 OK AP836A CN8030R240 voltage=5.10 Voltage 03 OK AP836A CN8030R282 voltage=11.86 Voltage 04 OK AP836A CN8030R282 voltage=5.08 Voltage 05 OK 592267-001 CN8028N722 voltage=12.00 Voltage 06 OK 592267-001 CN8028N722 voltage=5.13 Voltage 07 OK 592267-001 CN8028N722 voltage=3.68 Voltage 08 OK 592267-001 CN8028N723 voltage=11.98 Voltage 09 OK 592267-001 CN8028N723 voltage=5.11 Voltage 10 OK 592267-001 CN8028N723 voltage=3.70 Disk 01 OK 582939-001 2S6034B176 addr=0 Disk 02 OK 582939-001 2S6034B176 addr=1 Disk 03 OK 582939-001 2S6034B176 addr=2 Disk 04 OK 582939-001 2S6034B176 addr=3 Disk 05 OK 582939-001 2S6034B176 addr=4 Disk 06 OK 582939-001 2S6034B176 addr=5 Disk 07 OK 582939-001 2S6034B176 addr=6 Disk 08 OK 582939-001 2S6034B176 addr=7 Disk 09 OK 582939-001 2S6034B176 addr=8 Disk 10 OK 582939-001 2S6034B176 addr=9 Disk 11 OK 582939-001 2S6034B176 addr=10 Disk 12 OK 582939-001 2S6034B176 addr=11 Disk 13 Absent 582939-001 2S6034B176 addr=12 Disk 14 Absent 582939-001 2S6034B176 addr=13 Disk 15 Absent 582939-001 2S6034B176 addr=14 Disk 16 Absent 582939-001 2S6034B176 addr=15 Disk 17 Absent 582939-001 2S6034B176 addr=16 Disk 18 Absent 582939-001 2S6034B176 addr=17 Disk 19 Absent 582939-001 2S6034B176 addr=18 Disk 20 Absent 582939-001 2S6034B176 addr=19 Disk 21 Absent 582939-001 2S6034B176 addr=20 Disk 22 Absent 582939-001 2S6034B176 addr=21 Disk 23 Absent 582939-001 2S6034B176 addr=22 Disk 24 Absent 582939-001 2S6034B176 addr=23 ------------------------------------------------------------------------------- SKU --- Part Number: AP846A Serial Number: 2S6034B176 Revision: C FRU --- Name: CHASSIS_MIDPLANE Description: SPS-CHASSIS 2U24 6G w/MIDPLANE Part Number: 582939-001 Serial Number: 2S6034B176 Revision: B Dash Level: FRU Shortname: Midplane/Chassis Manufacturing Date: 2010-07-03 08:01:02 Manufacturing Location: Longhua,Shenzhen,CN Manufacturing Vendor ID: 0x0000 FRU Location: MID-PLANE SLOT Configuration SN: 2S6034B176 FRU Status: OK FRU --- Name: RAID_IOM Description: HP P2000 G3 8G FC Array Controller Part Number: AP836A Serial Number: CN8030R240 Revision: C Dash Level: FRU Shortname: RAID IOM Manufacturing Date: 2010-07-20 19:45:36 Manufacturing Location: Longhua,Shenzhen,CN Manufacturing Vendor ID: 0x0000 FRU Location: UPPER IOM SLOT Configuration SN: 2S6034B176 FRU Status: OK FRU --- Name: RAID_IOM Description: HP P2000 G3 8G FC Array Controller Part Number: AP836A Serial Number: CN8030R282 Revision: C Dash Level: FRU Shortname: RAID IOM Manufacturing Date: 2010-07-19 21:57:48 Manufacturing Location: Longhua,Shenzhen,CN Manufacturing Vendor ID: 0x0000 FRU Location: LOWER IOM SLOT Configuration SN: 2S6034B176 FRU Status: OK FRU --- Name: POWER_SUPPLY Description: FRU,Pwr Sply,595W,AC,2U,LC,HP Part Number: 592267-001 Serial Number: CN8028N722 Revision: C Dash Level: FRU Shortname: AC Power Supply Manufacturing Date: 2010-07-10 08:06:53 Manufacturing Location: Shenzhen,Guangdong,CN Manufacturing Vendor ID: 0x048F FRU Location: LEFT PSU SLOT Configuration SN: 2S6034B176 FRU Status: OK FRU --- Name: POWER_SUPPLY Description: FRU,Pwr Sply,595W,AC,2U,LC,HP Part Number: 592267-001 Serial Number: CN8028N723 Revision: C Dash Level: FRU Shortname: AC Power Supply Manufacturing Date: 2010-07-10 08:21:11 Manufacturing Location: Shenzhen,Guangdong,CN Manufacturing Vendor ID: 0x048F FRU Location: RIGHT PSU SLOT Configuration SN: 2S6034B176 FRU Status: OK Info: * Rates may vary. This is normal behavior. Success: Command completed successfully.